Switches and Disconnectors

INDOOR TRIPOLAR DISCONNECTOR

Ranges:12, 24 and 36 kV; 400 and 630A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Double knives in nickel-plated hard copper
    • Epoxy resin insulators
    • Vertical or horizontal mounting


Applications:
Substations, transformation stations, MT cells.

Norms:IEC 62271-102, IEC 62271-103.

INDOOR TRIPOLAR DISCONNECTOR

Ranges:12, 24 and 36 kV; 400 and 630A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Double knives in nickel-plated hard copper
    • Epoxy resin insulators
    • Vertical or horizontal mounting


Applications:
Substations, transformation stations, MT cells.

Norms:IEC 62271-102, IEC 62271-103.

INDOOR TRIPOLAR DISCONNECTOR

Ranges:17.5 kV; 400A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Double knives in nickel-plated hard copper
    • Epoxy resin insulators
    • Vertical or horizontal mounting


Applications:
Substations, transformation stations, MT cells.

Norms:IEC 62271-102, IEC 62271-103.

INDOOR TRIPOLAR DISCONNECTOR

Ranges:17.5 kV; 400A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Double knives in nickel-plated hard copper
    • Epoxy resin insulators
    • Vertical or horizontal mounting


Applications:
Substations, transformation stations, MT cells.

Norms:IEC 62271-102, IEC 62271-103.

OUTDOOR TRIPOLAR DISCONNECTOR

Ranges:17.5 and 36 kV; 200, 400 and 630A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with galvanized cast exterior hardware
    • Horizontal mounting, Pole to Pole


Applications:
Sectioning of MT aerial networks

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-164.

OUTDOOR TRIPOLAR DISCONNECTOR

Ranges:17.5 and 36 kV; 200, 400 and 630A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with galvanized cast exterior hardware
    • Horizontal mounting, Pole to Pole


Applications:
Sectioning of MT aerial networks

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-164.

OUTDOOR TRIPOLAR DISCONNECTOR

Ranges:12/17.5 and 36 kV; 200, 400 and 630A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with galvanized cast exterior hardware
    • Vertical mounting


Applications:
Aerial transformer stations, MV substations, MV aerial networks

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-164.

OUTDOOR TRIPOLAR DISCONNECTOR

Ranges:12/17.5 and 36 kV; 200, 400 and 630A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with galvanized cast exterior hardware
    • Vertical mounting


Applications:
Aerial transformer stations, MV substations, MV aerial networks

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-164.

INDOOR TRIPOLAR SWITCH-DISCONNECTOR

Ranges: 12, 17.5 e 24kV (400A) e 36kV (630A)

Short circuit current: 63kA (12, 17.5 e 24kV) e 50kA (36kV)

Stipulated short-time current: 18kA, 3s (12, 17,5 e 24kV) e 14kA, 3s (36kV)

Special Features:

    • Double bimetal knives (copper + aluminum)
    • Epoxy resin insulators
    • Closing and opening abruptly
    • Independent maneuver
    • Mounting in any position with guaranteed cutting power
    • Cutting speed independent of the maneuver


Applications:
MV substations, MV/LV transformation stations

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-166.

INDOOR TRIPOLAR SWITCH-DISCONNECTOR

Ranges: 12, 17.5 e 24kV (400A) e 36kV (630A)

Short circuit current: 63kA (12, 17.5 e 24kV) e 50kA (36kV)

Stipulated short-time current: 18kA, 3s (12, 17,5 e 24kV) e 14kA, 3s (36kV)

Special Features:

    • Double bimetal knives (copper + aluminum)
    • Epoxy resin insulators
    • Closing and opening abruptly
    • Independent maneuver
    • Mounting in any position with guaranteed cutting power
    • Cutting speed independent of the maneuver


Applications:
MV substations, MV/LV transformation stations

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-166.

INTERIOR TRIPOLAR FUSE SWITCH-DISCONNECTER

Ranges: 12, 17.5 e 24kV (400A) e 36kV (630A)

Short circuit current: 63kA (12, 17.5 e 24 kV) e 50kA (36kV)

Stipulated short-time current: 18kA, 3s (12, 17.5 e 24kV) e 14kA, 3s (36kV)

Special Features:

    • Double bimetal knives (copper + aluminum)
    • Epoxy resin insulators
    • Closing and opening abruptly
    • Independent maneuver
    • Mounting in any position with guaranteed cutting power
    • Cutting speed independent of the maneuver


Applications:
MV substations, MV/LV transformation stations

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-167.

INTERIOR TRIPOLAR FUSE SWITCH-DISCONNECTER

Ranges: 12, 17.5 e 24kV (400A) e 36kV (630A)

Short circuit current: 63kA (12, 17.5 e 24 kV) e 50kA (36kV)

Stipulated short-time current: 18kA, 3s (12, 17.5 e 24kV) e 14kA, 3s (36kV)

Special Features:

    • Double bimetal knives (copper + aluminum)
    • Epoxy resin insulators
    • Closing and opening abruptly
    • Independent maneuver
    • Mounting in any position with guaranteed cutting power
    • Cutting speed independent of the maneuver


Applications:
MV substations, MV/LV transformation stations

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-167.

OUTDOOR TRIPOLAR SWITCH-DISCONNECTOR

Ranges:17.5 and 36 kV; 200 and 400A

Short circuit current:25 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with external galvanized casting hardware -17.5 and 36kV
    • Vertical or horizontal mounting


Applications:
Aerial transformation stations, MT aerial networks

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-166.

OUTDOOR TRIPOLAR SWITCH-DISCONNECTOR

Ranges:17.5 and 36 kV; 200 and 400A

Short circuit current:25 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with external galvanized casting hardware -17.5 and 36kV
    • Vertical or horizontal mounting


Applications:
Aerial transformation stations, MT aerial networks

Norms:IEC 62271-102, IEC 62271-103, E-Redes DMA-C64-166.

OUTDOOR TRIPOLAR SWITCH-DISCONNECTOR

Ranges:17.5 and 36 kV; 400A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with galvanized cast exterior hardware
    • Vertical mounting


Applications:AI type aerial transformer stations

Norms:IEC 62271-102, IEC 62271-103.

OUTDOOR TRIPOLAR SWITCH-DISCONNECTOR

Ranges:17.5 and 36 kV; 400A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with galvanized cast exterior hardware
    • Vertical mounting


Applications:
AI type aerial transformer stations

Norms:IEC 62271-102, IEC 62271-103.

OUTDOOR TRIPOLAR FUSE DISCONNECT SWITCH

Ranges:17.5 and 36 kV; 400A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with galvanized cast exterior hardware
    • Vertical mounting


Applications:
Aerial transformer stations, MV substations, MV aerial networks

Norms:IEC 62271-102, IEC 62271-103.

OUTDOOR TRIPOLAR FUSE DISCONNECT SWITCH

Ranges:17.5 and 36 kV; 400A

Short circuit current:31.5 kA

Stipulated short-time current:12.5kA, 3s

Special Features:

    • Hot dip galvanized structure
    • Porcelain insulators with galvanized cast exterior hardware
    • Vertical mounting


Applications:
Aerial transformer stations, MV substations, MV aerial networks

Norms:IEC 62271-102, IEC 62271-103.

Headquarters
Rua de Murraceses 550,
4415-490 Grijó, Vila Nova de Gaia
Phone: 22 747 0250(Call to national landline network)
Delegation
Sitio Work Sete Rios
Praça Nuno Rodrigues dos Santos 7 (room 19)
1600-171 Lisbon